The Air Self-purifier from HVAC Technology is a portable, recirculating air purification unit designed for office environments. Available in both ceiling-mounted and mobile configurations, it is an ideal choice for offices, cleanrooms, and precision manufacturing workstations (supporting cleanroom classes ranging from ISO3 to ISO 8, or Class 100 to Class 300,000), making it well-suited for bulk procurement by enterprises.
The unit provides high-precision air filtration, achieving an air cleanliness level of ISO Class 5 (Class 100) at the air outlet.

Key Features
Filtration and Sterilization: Going beyond conventional particulate capture, this air purifier utilizes a multi-stage HEPA filtration system capable of trapping microscopic pollutants with an efficiency of ≥99.97%. The unit can be equipped with an integrated UVC germicidal module and a bipolar ionization module, effectively neutralizing up to 99.99% of airborne viruses, bacteria, and mold spores to ensure a biologically safe breathing environment.
Materials and Construction: The housing is crafted from high-strength cold-rolled steel with a corrosion-resistant coating; it offers a premium, cool-to-the-touch feel and a robust, durable structure.
Low-Noise Centrifugal Fan: Featuring a quiet fan system-complemented by primary and HEPA filters-the unit offers adjustable speed settings, including a dedicated "sleep" mode that minimizes noise to ensure an undisturbed workspace.
Versatile Mobility: Equipped with silent, omnidirectional casters at the base (floor-standing model), the unit can be easily moved between offices, conference rooms, and reception areas as needed.
Easy Deployment: Whether suspended above critical workstations or positioned within commercial spaces, the unit provides an immediate improvement in air quality, meeting the stringent cleanliness standards required for commercial, industrial, and medical environments.
Specifications
|
Parameter |
ZJ-600 |
ZJ-800 |
|
Filtration efficiency |
≥99.97%@≥0.5μm |
≥99.97%@≥0.5μm |
|
Average wind speed |
0.30m/s~0.60m/s |
0.30m/s~0.60m/s |
|
Vibration / half peak |
≤4μm(X,Y,Z direction) |
≤4μm(X,Y,Z direction) |
|
Noise |
≤62dB(A) |
≤62dB(A) |
|
Rated air flow |
800m³/h |
1000m³/h |
|
Maximum power consumption |
≤0.3KW |
≤0.3KW |
|
Cabinet material |
High quality steel plate spray |
High quality steel plate spray |
|
Power Supply |
AC,Single-phase220V/50Hz |
AC,Single-phase220V/50Hz |
|
Weight |
~50kg |
~60kg |
|
Device size (W×D×H, mm) |
720×720×450 |
940×720×450 |
|
Installation opening size (mm) |
660×660 |
870×660 |
|
HEPA filter specification |
600×600×150×1 |
820×600×150×1 |
Installation Guide for Portable Recirculating Air Purifiers (for Office Use)
Pre-installation Checks
Inspect the unit for any dents or damage to the casing, and ensure the filter packaging is intact. For floor-standing models, verify that all universal casters and braking components are present. Position the unit away from obstructions such as curtains, stacks of documents, or plants; ensure the air inlets and outlets remain unobstructed, and keep the unit away from heat sources.
Assembly Steps (for floor-standing models with casters)
Place the unit flat (bottom side up; use a soft cloth underneath to prevent scratching the casing).
Install the four silent universal casters and tighten the mounting screws; ensure at least two of the casters are equipped with brakes.
Remove the plastic protective film from the filters (this is crucial-if the film is not removed, air intake will be completely blocked).
Insert the filters in the following order: Pre-filter → HEPA filter → Activated carbon filter (if applicable).
Close the filter compartment door, ensuring it is securely latched and properly sealed.
Powering On and Testing
Ensure the unit's power switch is in the "off" position before plugging the power cord into a 220V mains outlet. Power on the unit and run it on a low setting for 5–10 minutes. Verify that the fan speed settings function correctly. Observe the unit to ensure the fan runs smoothly, without any unusual noises or odors.
FAQ
Q: What is the difference between a portable office air purifier and a ceiling-mounted air purification unit for cleanrooms?
A: Portable office air purifier: Mobile and requires no installation; designed solely to improve air quality in standard offices. It does not achieve specific cleanroom classification standards and cannot maintain pressure differentials between rooms.
Cleanroom air purification unit: Fixed-mounted to the reinforced grid of a cleanroom ceiling system. It features high airflow and pressure, and is used to maintain the required cleanliness class in GMP-compliant cleanrooms (typically integrated with cleanroom wall panels and specialized doors).
Q: What is the coverage area for a single floor-standing unit?
A: For standard commercial models, a coverage area of 15–40㎡ is recommended. For spaces larger than 40㎡, it is advised to use multiple units distributed throughout the area.
Q: Can it run continuously throughout the day in an enclosed meeting room?
A: Yes, it can continuously circulate air to remove particulate matter and odors. However, since CO₂ levels can accumulate in an enclosed space, it is recommended to open a window for brief ventilation every 1–2 hours.
Hot Tags: air self-purifier, China air self-purifier manufacturers, suppliers, factory, Air Self Purifier, cleanroom, cleanroom materials, Purification Accessories, Purification Lamps, T GRID Ceiling