The HVAC Technology industrial-grade HEPA air filtration unit features a durable cold-rolled steel housing with an electrostatic powder-coated finish. It is designed to efficiently remove particulate matter from cleanroom environments in industrial facilities. As a terminal filtration solution, it offers low initial investment and easy on-site installation, ensuring consistent air quality in cleanrooms. It is an economical and efficient choice for the construction or renovation of cleanrooms in sectors such as electronics, pharmaceuticals, and food processing.

Key Features
Robust and Durable
The main housing is constructed from industrial-grade steel and finished with a high-density electrostatic coating. This provides effective resistance against corrosive substances and scratches, ensuring long-term structural integrity even in demanding production environments.
Energy-Efficient
Equipped with a HEPA filter that achieves 99.99% filtration efficiency for 0.3μm particles, the unit features an optimized airflow design. This allows air to pass through the filter medium with less power consumption, significantly reducing overall energy usage and operational costs.
Professional Design
The internal geometry is specially engineered to eliminate turbulent air pockets. As air exits the diffuser panel, it transitions into a gentle, uniform laminar flow that covers the entire production area, ensuring an ideal air pressure distribution.
Specifications
| Specification | High Efficiency Filter Size (mm) | Efficiency |
Overall Dimension Length × Width × Height (mm) |
Rated Air Flow (m³/h) | Top Duct | Side Duct | Diffuser Plate | |
| Top Air | Side Air | |||||||
|
GK-5A |
GK-5IIA |
320×320×220 |
99.99% |
370×370×500 |
500 |
200×200 |
200×200 |
430×430 |
|
GK-10A |
GK-10IIA |
484×484×220 |
99.99% |
530×530×500 |
1000 |
320×200 |
320×200 |
600×600 |
|
GK-15A |
GK-15IIA |
630×630×220 |
99.99% |
680×680×500 |
1500 |
320×250 |
400×200 |
740×740 |
|
GK-20A |
GK-20IIA |
968×484×220 |
99.99% |
1020×530×500 |
2000 |
400×250 |
500×200 |
1080×600 |
|
GK-30A |
GK-30IIA |
1260×630×220 |
99.99% |
1310×680×500 |
3000 |
500×320 |
630×250 |
1370×740 |
Precautions for HEPA Filter Installation
Before construction, carefully study the cleanroom architectural drawings to precisely locate and prepare the installation openings within the ceiling grid. The spacing of these openings must align with the air supply coverage required for the production line; plan accordingly to eliminate any "dead zones" in the airflow.
Use compliant industrial-grade hangers to hoist the heavy-duty steel HEPA filter housings into the designated ceiling openings. Secure them firmly with bolts and reinforce all mounting components to ensure the support structure can fully bear the weight of the equipment. A rigid, stable installation prevents vibrations or swaying-such as those caused by the starting or stopping of fans-thereby ensuring a stable, laminar airflow within the cleanroom.
Gently place the fiberglass filter into the gel-seal (DOP) channel. Apply even downward pressure to ensure the gel gasket seats firmly against the frame, creating a reliable, airtight seal. Engage the mechanical locking clips; an audible "click" confirms that the filter is correctly seated, preventing potential air leaks at the joints due to fluctuations in system pressure.
Connect the top or side-mounted air ducts (as specified in the design) to the central HVAC supply system. Seal all metal-to-metal joints using both industrial sealing tape and sealant to eliminate air leakage and maintain stable static pressure within the plenum.
Attach the perforated diffuser plate to the air outlet at the bottom of the filter housing. Use the leveling screws to make fine adjustments to the orientation and angle, ensuring that the clean air flows downward in a uniform, laminar pattern to provide a continuous supply of sterile, clean air to the core production area.
Activate the central air supply system and observe the airflow. Use an anemometer to measure the air velocity and uniformity across the diffuser plate. Conduct a comprehensive DOP/PAO aerosol leak test to verify the integrity of the seal and the filtration efficiency of the installed unit.
Record the initial pressure differential and baseline airflow data in the equipment maintenance log. Affix a permanent nameplate to the exterior of the housing-noting the model, installation date, and scheduled maintenance intervals-to facilitate future inspections and upkeep. Finally, complete the project by obtaining the necessary sign-off and acceptance.
FAQ
Q: What are the criteria for replacing a HEPA filter?
A: The primary criterion is the pressure differential reading across the filter housing. When the pressure drop across the filter reaches the design-specified final resistance, the filter element must be replaced. Routine maintenance logs should record the initial baseline pressure differential, which serves as a reference for periodic monitoring. Additionally, immediate replacement is required if the filter fails a DOP leak test, if the filter media is damaged, or if there is significant contamination.
Q: What actions during the installation process are likely to cause damage to the filter?
A: Bumping or striking the glass fiber filter media during handling or installation; applying uneven pressure when seating the filter, which can deform the filter frame; overtightening locking mechanisms, which may crush the filter element; and allowing construction dust or oil/grease to contaminate the filter surface. HEPA filter media is extremely fragile; it must be handled with great care during installation, and the construction area must be kept clean.
Q: What key parameters should be verified during the ceiling cutout/opening preparation phase?
A: Refer to the architectural drawings to confirm the dimensions and spacing of the openings. Ensure that the air supply coverage aligns with the production line below to avoid "dead zones" (areas with no airflow). Furthermore, verify the load-bearing capacity of the ceiling structure to ensure that the ceiling framework can support the combined weight of the HEPA filter housing, suspension hardware, and air ducts.
Hot Tags: hepa box, China hepa box manufacturers, suppliers, factory, Air Self Purifier, Air Shower, cleanroom, Purification Accessories, Purification Lamps, T GRID Ceiling