Purification Lamps

Designed specifically for cleanrooms, this lighting fixture serves as an essential component of air purification and disinfection systems. It is used in clean environments—such as dust-free workshops, GMP-compliant facilities, and laboratories—to eliminate bacteria, viruses, molds, and other contaminants, thereby improving indoor air quality and ensuring a safe working environment. Key requirements include being dust-free, resistant to dust accumulation, highly airtight, and featuring a smooth, easy-to-clean surface; it is a core component integrated into cleanroom systems.
Send Inquiry
Description
Product Introduction

Designed specifically for cleanrooms, this lighting fixture serves as an essential component of air purification and disinfection systems. It is used in clean environments-such as dust-free workshops, GMP-compliant facilities, and laboratories-to eliminate bacteria, viruses, molds, and other contaminants, thereby improving indoor air quality and ensuring a safe working environment. Key requirements include being dust-free, resistant to dust accumulation, highly airtight, and featuring a smooth, easy-to-clean surface; it is a core component integrated into cleanroom systems.

1

 

Key Features and Advantages

 

The UV-C Germicidal Purification Lamps for Sterile Areas, manufactured by HVAC Technology (Suzhou) Co., Ltd., serve as core components in professional air purification and disinfection systems. They are specifically developed for B2B clients operating in sectors such as cleanroom construction, healthcare, and industrial purification.

 

This series of UV-C germicidal lamps utilizes a high-intensity 254nm UV-C light source-the optimal wavelength for microbial inactivation-capable of effectively eliminating 99.9% of airborne bacteria, viruses, molds, and other harmful microbial contaminants. The disinfection process requires no chemical agents, leaves no chemical residues, and creates no secondary pollution, making it an ideal physical disinfection solution for sterile environments.

 

The lamps are available in a variety of structural configurations and are housed in durable, aging-resistant materials. They are designed for seamless integration with Air Handling Units (AHUs) and cleanroom HVAC systems, providing continuous, dynamic disinfection of circulating air to effectively improve indoor air quality and maintain a stable, sterile operating environment.

 

These units are essential components for the construction of sterile facilities, meeting the rigorous disinfection standards required for healthcare settings, electronics cleanrooms, and industrial purification workshops. They provide consistent and reliable germicidal protection for B2B engineering projects.

 

The design-including structure, power output, and mounting method-can be customized to specific requirements. The units are engineered for easy assembly, disassembly, and inspection, simplifying routine maintenance and reducing long-term operational and maintenance costs.

 

2
3

 

Specifications

 

Parameter

Specification

Germicidal wavelength

254nm (optimal for pathogen elimination)

Main material

304 stainless steel, tempered glass, aluminum alloy

Product types

Stainless steel straight edge/bevel purifying lamp, explosion-proof fluorescent lamp, LED flat plate purifying lamp, embedded grille purifying lamp, bending rod germicidal lamp

Installation mode

Surface-mounted, embedded, suspended, grille-type

Protection grade

Standard model: IP44; Explosion-proof model: IP65

Power range

18W-80W (LED model: 20W-40W)

Service life of tube

≥8000 hours (UV-C tube); ≥50000 hours (LED chip)

Applicable air speed

0.5-2.0m/s (matching HVAC systems)

Sterile coverage

≥99.9% for airborne bacteria/viruses

Applicable temperature

-5℃ to 40℃

 

Installation Details for UV-C Germicidal Purification Lamps in Sterile Areas

Pre-installation Inspection

 

Inspect the exterior of the lamps, power specifications, and the integrity of the germicidal tubes. Verify the model number to ensure it is compatible with the airflow capacity of the HVAC system and the available installation space.

Prepare the necessary installation hardware (stainless steel brackets, mounting screws, and waterproof gaskets) along with professional tools (insulated screwdrivers, multimeters). Ensure that the designated installation area is fully wired and equipped with proper grounding protection.

Check the cleanliness of the installation sites-such as HVAC air ducts or cleanroom ceilings-to prevent dust from accumulating on the surface of the germicidal tubes, which could otherwise reduce disinfection efficiency.

Installation Procedures by Model Type

 
  • Surface-mounted/Suspended Lamps: Use expansion bolts to secure the stainless steel brackets to the wall or ceiling, then attach the lamps to the brackets. Install waterproof gaskets and tighten the mounting screws to ensure a proper seal.
  • Recessed/Grille-type Models: Insert the lamps into the pre-cut openings in the cleanroom ceiling or HVAC air ducts. Connect the wiring to the HVAC system control panel to enable integrated, automated control.
  • Explosion-proof Models: Installation must strictly adhere to industrial explosion-proof standards. Utilize flameproof fittings and sealed electrical connections to mitigate the risks of gas leakage and potential ignition.

Post-installation commissioning

 

Conduct a 30-minute no-load test run to verify that the lighting units illuminate correctly and that the electrical circuits operate stably; ensure there are no abnormal noises, overheating, or other issues.

Integrate the lighting units into the HVAC system, test their germicidal performance under various airflow velocity conditions, and adjust their operating duration based on the air change rate of the cleanroom.

Use professional testing equipment to calibrate the UV germicidal irradiance intensity, ensuring it meets the disinfection standards for sterile zones (≥1000 μW/cm²).

Precautions

 

UV-C (254 nm) radiation can cause severe burns to the eyes and skin. Direct exposure of eyes or skin to UV-C light is strictly prohibited.

The main power supply must be disconnected before performing any installation, inspection, maintenance, or lamp replacement.

Equipped with a safety interlock: The UV lamps will automatically power off when the AHU (Air Handling Unit) access door is opened, preventing accidental UV exposure.

UV-C lamps must not be operated outside of air ducts or equipment casings. Direct UV radiation in areas occupied by people is strictly prohibited.

Wear protective gloves when handling the lamps; do not touch the quartz glass surface with bare hands, as oils and residues can cause the lamps to burn out.

Keep flammable materials away from the lamps while the equipment is in operation.

 