Cleanroom HEPA Filter

Cleanroom HEPA filters serve as critical terminal filtration units in cleanroom systems. Utilizing precise physical interception mechanisms, they capture particles ≥0.3 μm from gas-solid flows, thereby ensuring the required air cleanliness for production or experimental environments. As core components of purification systems, these filters are designed for use in cleanrooms and various industrial settings, meeting the rigorous ISO 14644-1 (Classes 1–9) standards for controlled environments.
Send Inquiry
Description
Product Introduction

Cleanroom HEPA filters serve as critical terminal filtration units in cleanroom systems. Utilizing precise physical interception mechanisms, they capture particles ≥0.3 μm from gas-solid flows, thereby ensuring the required air cleanliness for production or experimental environments. As core components of purification systems, these filters are designed for use in cleanrooms and various industrial settings, meeting the rigorous ISO 14644-1 (Classes 1–9) standards for controlled environments.

5

 

 

 

 

 

Key Advantages

Guaranteed Quality

Each filter is manufactured in our ISO-, UL-, and ASHRAE-certified facilities. Featuring a robust outer frame and a solid, substantial build, the tightly pleated internal filter media is engineered to withstand fluctuations in air pressure without tearing or shedding.

Contamination Control

These high-efficiency filters not only capture airborne particles but also block the spread of microorganisms. In environments such as pharmaceutical cleanrooms, biological laboratories, and operating rooms, they provide essential biological isolation and help mitigate the risk of cross-contamination. Furthermore, this filtration capability protects expensive HVAC system components from premature wear, damage, and internal clogging, thereby extending the overall service life of the infrastructure.

System Efficiency

Utilizing a multi-stage filtration control strategy, the system dynamically manages airflow resistance. This intelligent design prevents sudden spikes in energy consumption, striking an optimal balance between maximum purification efficiency and long-term operational cost savings for large-scale industrial facilities.

 

1
2

 

Specifications

 

The precise technical parameters for each stage of filtration are listed below; this data can serve as a reference for procurement managers.

 

FiltrationGrade

EfficiencyStandard

MainFilteringObjects

InitialResistance

(Pa)

CommonStructure

Pre-filter (G1-G4)

EN779, ≥5μm particles 40%-90%

Large particulate impurities

30-50

Plate type, pleated type

Medium efficiency (F5-F9)

EN779,≥1μm particles60%-95%

1-5μm suspended particles

50-90

Bag type, pleated type

Sub-high efficiency(H10-H11)

EN1822,0.3μm particles 95%-99.95%

Tiny particles, some microorganisms

100-150

Pleated type, non-pleated type

High efficiency(HEPA,H12-H14)

EN1822,H13 grade ≥99.97%

MPPS particles, bacterial and viral carriers

150-250

Partitionless and Partitioned Types

Ultra-High Efficiency(ULPA,U15-U17)

EN1822,U15 grade≥99.999%

Nanoscale Particles, Viruses

200-300

Partitionless Pleated Type

 

Product Performance

01/

Panel Filters: Featuring a simple, robust construction, these filters utilize moisture-resistant synthetic fibers. Their primary advantages include low initial investment and a compact filtration media area; they are designed to build up resistance relatively quickly, making them ideal for the initial pre-filtration stage in commercial HVAC systems.

02/

Bag Filters: These are the mainstream choice for medium-efficiency filtration. Built with a high-strength frame, they remain resistant to deformation even under high airflow conditions. They offer an adjustable filtration area, a high dust-holding capacity, and low air resistance. Their convenient bag-style design simplifies handling and replacement, making them the preferred option for medium-to-large airflow applications.

03/

Pleated Filters: These utilize high-density, folded filtration media to maximize the effective surface area within a minimal volume. The structural integrity of the pleats ensures consistent spacing, making them well-suited for medium-to-low efficiency filtration, while preventing the media from collapsing under pressure.

04/

Separatorless High-Efficiency Filters: These filters utilize hot-melt adhesive strands to support and separate the pleats, replacing the traditional metal or paper separators found in older designs. They are currently the most widely used terminal high-efficiency filtration products in cleanroom applications. Constructed from continuously pleated ultra-fine glass fiber filter media, they are available in H13 and H14 efficiency grades, with U15 ultra-low penetration air (ULPA) versions also offered.

05/

High-Efficiency Filters with Separators: Featuring corrugated aluminum separators and specialized filter media, these units offer exceptional resistance to temperature and humidity. The separators provide structural support for the filter layers-composed of ultra-fine glass fiber media-ensuring high stability; the pleat pack remains resistant to collapse or deformation, even when subjected to fluctuations in system air pressure.

 

3
4

 

HVAC Technology offers highly specialized material options, including activated carbon layers for the removal of volatile organic compounds (VOCs) and odors, as well as antimicrobial and antiviral coatings. These customized solutions are perfectly tailored to the requirements of high-end sectors such as biomedicine, semiconductors and microelectronics, and healthcare.

 