Cleanroom Sandwich Panels

Cleanroom sandwich panels are composite panels specifically designed for the enclosures of cleanroom environments. Featuring a smooth, seamless surface that resists dust accumulation, these panels meet the stringent requirements for dust control, airtightness, fire resistance, and moisture protection in cleanrooms. Cleanroom sandwich panels manufactured by HVAC Technology are used for cleanroom partition walls, ceilings, and localized partitions, ensuring compliance with standards such as ISO 14644 and GMP.
Send Inquiry
Description
Product Introduction

Cleanroom sandwich panels are composite panels specifically designed for the enclosures of cleanroom environments. Featuring a smooth, seamless surface that resists dust accumulation, these panels meet the stringent requirements for dust control, airtightness, fire resistance, and moisture protection in cleanrooms. Cleanroom sandwich panels manufactured by HVAC Technology are used for cleanroom partition walls, ceilings, and localized partitions, ensuring compliance with standards such as ISO 14644 and GMP.

1

 

Key Advantages and Features

01/

Cleanroom Compatibility: The surface is dense and smooth, generating no dust and resisting particle adhesion. Rounded corner transitions eliminate "dead zones" (hard-to-clean areas) and can withstand repeated wiping with alcohol or chlorine-based disinfectants, meeting GMP cleaning validation standards. Anti-static versions are available to prevent electrostatic discharge (ESD) from damaging chips or attracting dust.

02/

Modular Dry Construction: Panels are prefabricated in the factory and assembled on-site. This "dry" installation method-requiring no cement or mortar-accelerates construction, minimizes on-site dust, and facilitates future modifications, dismantling, or relocation.

03/

Thermal Insulation: The core material acts as a thermal break, reducing the load on cleanroom HVAC systems and enhancing energy efficiency.

04/

Fire Safety: Class A fire-rated core materials ensure compliance with fire safety regulations; the fire-resistance rating can be customized to meet specific project requirements.

05/

Airtightness: Featuring interlocking joints, integrated sealing strips, and rounded corner transitions, the system minimizes air leakage in cleanrooms and helps maintain stable room pressure differentials.

 

Specifications

 

Specification Item

Standard Parameters

Core Material

Medium & high-density rockwool / glass wool

Face Sheet

Galvanized steel / 304 stainless steel / color-coated steel

Standard Width

950mm, 1150mm

Standard Thickness

50mm, 75mm, 100mm, 150mm, 200mm

Joint Type

Tongue-and-groove / corrugated

Fire Rating

Grade A

Thermal Conductivity

≤0.045 W/(m·K)

Sound Insulation

≥30dB (100mm panel)

Working Temperature

-40℃ ~ 200℃

Surface Treatment

Electrostatic spraying, galvanizing, polishing

 

2001
3001

 

Construction Guidelines and Acceptance Standards

Construction Principles
  • Protection of panels upon arrival: Retain the PE protective film and remove it only before final acceptance to prevent scratches and contamination.
  • Layout first, followed by the installation of U-shaped aluminum tracks (floor and ceiling channels); interlock the male and female panel joints and verify vertical alignment.
  • All internal corners must utilize radiused (curved) aluminum profiles; right-angled corners are prohibited. Seal all wall penetrations for utilities with fire-resistant materials and apply continuous sealant to all gaps.
  • Ceiling panels must be installed using compatible T-shaped aluminum profiles and threaded suspension rods, selected based on load requirements; reinforced manual-assembly panels are required for ceilings designed to support foot traffic.
Key Acceptance Criteria
  • Appearance: Panel surfaces must be free of dents, scratches, or coating defects.
  • Joints: Gaps must be uniform, and sealant lines must be continuous without breaks.
  • Documentation Verification: Fire resistance test reports, steel material certificates, and antimicrobial/antistatic test reports.
  • Leakage Testing: Conduct air leakage and pressure differential tests upon cleanroom completion to verify the airtightness of the enclosure system.

 

FAQ

 

Q: How do I choose between machine-made panels and handmade panels?

A: Machine-made panels: Produced on assembly lines; low cost; consistent flatness; suitable for large-area standard partition walls and general suspended ceilings. Handmade panels: Can incorporate internal reinforcing ribs; allow for increased thickness and custom-shaped cutouts; offer higher strength; suitable for load-bearing ceilings, door/window openings, and complex corner configurations; higher price point.

Q: What is the difference between cleanroom panels and standard color-steel sandwich panels?

A: Standard color-steel panels focus primarily on thermal insulation and enclosure. Cleanroom sandwich panels prioritize specific performance criteria: dust-free properties, surfaces that withstand repeated disinfection, no dust-trapping dead zones, sealed joints, and optional anti-static or antibacterial capabilities. They are used with a full suite of radiused aluminum profiles to meet cleanroom validation standards-capabilities that standard color-steel panels cannot match.

Q: Can personnel walk directly on cleanroom sandwich panels?

A: Walking on standard 50mm machine-made ceiling panels is strictly prohibited. If maintenance access is required, custom-made, load-bearing handmade cleanroom panels must be used, supported by reinforced, thickened, and ribbed load-bearing profiles.

 

Hot Tags: cleanroom sandwich panels, China cleanroom sandwich panels manufacturers, suppliers, factory, Cleanroom Sandwich Panels, cleanroom wall panels

Send Inquiry

Send Inquiry